FL 03.1 – Series and Parallel Pumps
With this equipment, a large list of the operations can be put into practice, both start-up, operation and regulation necessary in a pumping installation.
Description
One of the pumps is controlled by a frecuency inverter, which allows the speed of rotation to be varied. This pump has also a measurement system of mechanical torque.
The flow rate is measured by an electronic flow meter.
In addition, the study of the characteristics of a pump can be carried out, working individually and in a group, in series or in parallel, carrying out a wide range of experiments and experiences.
Learning Objectives
- Start-up of a pump, analysis and study of different aspects to consider.
- Priming pump.
- Checking the sense of rotation.
- Overcurrent produced in the engine.
- Study and obtain the characteristic curves of a pump.
- Height – flow (H-Q).
- Hydraulic power – flow (P-Q).
- Torque – flow (M-Q).
- Mechanical efficiency – flow (hm-Q).
- Mechanical power – flow (Pm – Q).
- Efficiency of the engine – flow (he-Q).
- Electric power – flow (Pe-Q).
- Total efficiency – flow (h-Q).
- Study of cavitation, and obtaining the N.P.S.H. Curve required-flow.
- Study of the different forms of regulating a pump. Checking similarity laws.
- Variation of the rotational speed. Obtaining the new characteristic curves.
- Changing the operating point by varying the pumping installation.
- Manoeuvred of the discharge valve.
- Analysis of the same and different pumps working in group.
- Characteristic curves operating in serie.
- Height – flow (H-Q).
- Power – flow (P-Q).
- Efficiency – flow (h-Q).
- Characteristic curves operating in parallel.
- Height – flow (H-Q).
- Power – flow (P-Q).
- Efficiency – flow (h-Q).
Technical Data
Internal diameters:
- Suction pipe
- Øinterior = 45,2 mm.
- Øexterior = 50 mm.
- Drive pipe
- Øinterior = 34 mm.
- Øexterior = 40 mm.
Tank:
- Capacity: 250 litros
Manometers:
- Bourdon type with glycerin from –10 to 70 m wc.
- Bourdon type with glycerin from –10 to 35 m wc. (x3)
Pumps characteristics:
- Maximum manometric height 24 m wc.
- Flow: 20 / 120 l/min.
- Manometric height: 23 / 12 m wc.
- Consumed power 0,55 kW (0,75 HP).
- Turning speed 2900 r.p.m. (50 Hz).
Other elements:
- Electronic flowmeter 1200-50000 l/h
- Dynamometer 2 Kg x 10 gr.
- Wattmeters de 0 a 1200 W.
- Frecuency variator.
Requirements
- Power supply: 230V/50Hz.